Home > Error Accessing > Error Accessing External Object Property Value

Error Accessing External Object Property Value

I would like > to know how to assign a string value to computed field in a program. > > Thanks in advance > Joe "Austin Phillips" More about the author

Do a search on PBVM100.DLL and see if you come up with multiple copies with different versions. Cryptic Errors that Mean Something Some PowerBuider errors are very puzzling but they have predictable causes. Home » ExcelBanter forum » Excel Newsgroups » Excel Discussion (Misc queries) Error accessing external object property XVALUES Author Name Remember Me? Find all PBSHR050 (60) DLL's on the drive and determine whether the correct one is first in the path. http://stackoverflow.com/questions/16733829/error-accessing-external-object-property

Are you aComputer / IT professional?Join Tek-Tips Forums! Several dynamically assigned objects are reviewed: A Dynamic Bitmap, Icon, Cursor, etc. // assign a bitmap dynamically lm_mymenu.m_file.m_save.ToolBarItemName = "save2.bmp" All bitmaps, icons and cursors should either be included in the Not the answer you're looking for? To start viewing messages, select the forum that you want to visit from the selection below.

PC Review Home Newsgroups > Microsoft Excel > Microsoft Excel Misc > Home Home Quick Links Search Forums Recent Posts Forums Forums Quick Links Search Forums Recent Posts Articles Articles Quick Member Login Remember Me Forgot your password? Browse other questions tagged powerbuilder or ask your own question. either not set in script or not found in application INI file).

My code is very simple: ole_excel.Worksheets(l_engine).Activate //Ok ole_excel.ActiveSheet.ChartObjects(1).Activate //Ok ole_excel.ActiveChart.ChartTitle.Characters.Text = "Engine " + string(l_engine) //Ok ole_excel.ActiveChart.SeriesCollection(1).XValues = "=Engine"+ string(l_engine) + "!R2C1:R2C" + string(l_values) //Error!!! Is there another way to >do this sort of thing for a computed column? > >I do note that when I type the word 'Current', it gets highlighted like >a >keyword, You'll be able to ask any tech support questions, or chat with the community and help others. http://nntp-archive.sybase.com/nntp-archive/action/article/%[email protected]s%3E Have tried doing it running a macro in Excel directly with no luck.

It takes just 2 minutes to sign up (and it's free!). My >service actually creates this column in the datawindow when the >service is requested, and that part seems to work; at least, I >don't get any errors there. > >Can someone PowerBuilder EXEs should always behave the same as the development environment but this is not always the case. My >>>service actually creates this column in the datawindow when the >>>service is requested, and that part seems to work; at least, I >>>don't get any errors there. >>> >>>Can someone

PB060 (or PB050) does not exist This is usually occurs when the DBMS property for the transaction object is not properly initialized (e.g. https://scn.sap.com/thread/3784374 The trace file grows quickly so cause the application problem as soon as possible. Microsoft changed it's VBA object structure? In the variable declaration for that function, create a dummy variable for each dynamic windows and user objects: u_CalcPay luo_CalcPay w_CustDetail lw_CustDetail This will ensure that the dynamic windows and user

Is this because the column is a computd column? my review here About Us We're a friendly discussion community for Microsoft Office help and support. Thanks in advance, Nilov Serge -- Message posted from http://www.ExcelForum.com NilovSerge, Jun 21, 2004 #1 Advertisements Stephen Bullen Guest Hi, > It works FINE with Office97, 2000. Excel has columns limited to no more than 256 and rows no more than 65,536.

Environment Problem Once you have a clean EXE (with all dynamic objects included), you need to ensure that your runtime environment is set up properly. But still need to figure out what is the problem in Win7 64bit. –Alex May 24 '13 at 13:14 add a comment| Your Answer draft saved draft discarded Sign up First, trace the problem so you have figured out what is not working properly. click site Some components may not be visible.

Isn't that more expensive than an elevated system? These runtime DLL's should either be in the same directory as the application (i.e. Thanks! : jay Jay Schmidgall SunGard Securities Systems Sanjiv Das [TeamPS] Posted on 1998-01-29 10:04:37.0Z Newsgroups: sybase.public.powerbuilder.datawindowFrom: "Sanjiv Das [TeamPS]" Subject: Re: Error: Error accessing external object property ?Date: Thu, 29

I don't want to get lung cancer like you do Why are so many metros underground?

If you're having a computer problem, ask on our forum for advice. But when I tried to watch description of this object in low info windo I get error message "Cannot jump to "VBE" because it is in the library "VBIDE" which is The general method to do a thorough application regeneration and then to track down the problem in the EXE by tracing. What should I do?

asked 3 years ago viewed 3641 times active 3 years ago Visit Chat Related 1Does IsNull() guard against references to null objects?1How to create an array of User Objects in Powerbuilder?1Datawindow Conflicting DLL's Sometimes you might find that your application runs fine when it is running alone but it fails when another application at the same time. The error occurred when I tried to put a value on column 257+, So I change the way we save input the data into excel from columns to rows which has navigate to this website what is the good approach to make sure advisor goes through all the report?

Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free. Number Meaning 1 Divide by zero 2 Null object reference 3 Array boundary exceeded 4 Enumerated value is out of range for function 5 Negative value encountered in function 6 Invalid Newer Than: Search this thread only Search this forum only Display results as threads Useful Searches Recent Posts More... computed_column is, as the name suggests, a computed column.

Help if you can!! Computed fields ( defined in the DW painter using the 'Compute' button or selecting 'Computed Field' from the 'Objects' menu in the DW painter ) are not part of the result IM003 error: specified driver could not be loaded. Last resolution, do a SaveAs of your window and try again if it will work.

share|improve this answer answered May 24 '13 at 12:20 Sid 32711742 i will try on that. Thanks! >> >>: jay >>Jay Schmidgall >>SunGard Securities Systems >> > > Sanjiv Das [TeamPS] Posted on 1998-02-10 07:49:25.0Z Newsgroups: sybase.public.powerbuilder.datawindowFrom: "Sanjiv Das [TeamPS]" Subject: Re: Error: Error accessing external object All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. After doing l_ds_row.Retrieve(...), l_ds_row.rowcount() shows "1" for the first row as well as the second row of values from the tab delimited file.

Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum! Clearly, PowerSoft tries to keep these perfectly in synch but it does not always succeed. My >>service actually creates this column in the datawindow when the >>service is requested, and that part seems to work; at least, I >>don't get any errors there. >> >>Can someone Here's Why Members Love Tek-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More...

Red Flag This Post Please let us know here why this post is inappropriate. No, create an account now. The syntax is right what is wrong is the amount I was passing in the column. As one of >the functions of the service, I need to go through and set >the values of one (computed) column in every row. > >I've tried to do this two

Sergio sergio, Feb 7, 2007 #3 Albert0 Joined: Jan 10, 2012 Likes Received: 0 Hello I have this Error in powerbuilder : if ole_3.object.sourcecount <= 0 then //Error Because I Be sure that the DLL's deployed to users are the same versions as those used in the development environment -- otherwise the user might have problems that you can't duplicate in You can set the value of a computed column but not of a computed field. If you want to store values outside columns that are in the database, you should either use an external datawindow (has no DB relation) or add computed fields in your SQL